To aid a top-down construction sequence and the temporary works of a basement construction, columns can be installed into piles. These columns can be installed to tolerances of +/-10mm in plan and 1:400 verticality, given permanent installation tolerances.
Alongside plunge columns, we have also installed kingpost columns into piles, which act in a similar way but are pure temporary works so can be installed to different tolerances.
Our collaborative approach helps us develop the best for project solutions for you.